ZAM steel coating mass and strength for solar mounting. AI illustration.

A useful ZAM steel specification for solar mounting separates coating mass from steel strength, then matches both to the site and delivery plan. In Solaracks’ current procurement experience, 275 g/m² is the most common coating option and 350 MPa minimum yield strength is the regular requirement. Coatings of 310 or 350 g/m² need a specific stock check; if the required material is unavailable, custom production usually involves a larger order and longer lead time. A 550 MPa requirement normally needs special custom production.

For EPC buyers and mounting-system distributors, the sequence is: establish the site’s protection requirement, specify the complete material and section, then compare matching stock with a custom production route. This guide explains what to put in the enquiry for ground-mounted solar structures.

Terminology: ZAM™ is a Nippon Steel trademark. Here, the procurement discussion concerns zinc-aluminium-magnesium (Zn-Al-Mg) coated steel; the quotation must name the actual product and applicable standard. [1]

Keep coating mass, strength and section thickness separate

SpecificationMeaningRole in a mounting enquiry
275, 310 or 350 g/m²Total metallic alloy coating mass on both facesSurface protection, with the coating family and acceptance basis
350 or 550 MPaMinimum yield strength of the steel substrateMechanical requirement, with the full grade and applicable thickness range
Section thickness in mmThickness on the approved member drawingStructural sizing and manufacturing tolerance

“350” alone is ambiguous: 350 g/m² describes coating mass; 350 MPa describes steel strength. Increasing one does not automatically increase the other. A stronger steel grade also does not, on its own, permit a thinner section or wider support spacing.

Conceptual coated-steel cross-section: coating mass of 275, 310 or 350 g/m² is the total of both faces; no equal split is assumed. Steel strength is specified separately in MPa.
Coating mass is the total of both faces. Technical illustration, not to scale.

How to choose between 275, 310 and 350 g/m²

Start with exposure. Give the mounting supplier the project location, coastal or industrial conditions, and the specified corrosion category, if one has been assessed. Identify buried members, splash or standing water separately from above-ground exposure. Cuts, holes, joints and welds also belong in the finished-component protection review.

Choose the protection system before the delivery route. For the same coating family, a higher mass supplies more protective alloy per unit area. That makes 310 or 350 g/m² options to evaluate when the project calls for greater coating mass, including more demanding coastal or industrial exposure. A number alone does not qualify an entire racking system for a site. If the specification calls for C4 or C5, ask for the evidence supporting the proposed coating and finished details under those conditions.

Project situationPractical purchasing decision
No coating mass has been specifiedAsk for a proposal based on site exposure. Assess the commonly sourced 275 g/m² option against that requirement before accepting it.
The approved design specifies 310 or 350 g/m²Retain that requirement and request a matching stock check early. Compare custom production if stock is unavailable.
The supplier proposes a lower mass to meet the dateObtain technical approval for the substitution before ordering; availability does not establish suitability.
Buried, persistently wet or severe exposure is involvedReview the full protection system and details rather than treating a heavier coating as the complete solution.

A service-life calculation that divides coating mass by an assumed annual loss rate is conditional on that rate and its model assumptions. It is not a project warranty. This procurement guide uses the approved protection specification as the purchasing requirement rather than deriving a universal life from 275, 310 or 350 alone.

How thick is 275 g/m² in micrometres?

These values describe alloy coating mass, not pure zinc mass and not micrometres. For an illustrative equal split between faces, per-face thickness in µm equals total mass in g/m² divided by twice the coating density in g/cm³. Nippon Steel’s ZAM™ catalogue uses 6.0 g/cm³; ArcelorMittal gives 6.2 g/cm³ for Magnelis® and lists ZM310 at about 25 µm per face. [1, 2]

Total coating mass, both facesAt 6.0 g/cm³, per faceAt 6.2 g/cm³, per face
275 g/m²22.9 µm22.2 µm
310 g/m²25.8 µm25.0 µm
350 g/m²29.2 µm28.2 µm

This is a calculated comparison, rounded to 0.1 µm, assuming equal distribution. It is not a table of guaranteed minimum thicknesses or available mill products. Coating may be distributed unequally; acceptance follows the ordered product, standard and test method.

What does the coating acceptance basis mean?

A coating designation can specify a minimum average across test locations and a different minimum for an individual location. The following historical extracts in Nippon Steel U110en show why the number must travel with its standard. They explain terminology, not current contractual limits for every supplier. [1]

Catalogue extract and designationThree-spot minimum, both facesSingle-spot minimum, both faces
ASTM A1046/A1046M-09: ZMM275275 g/m²235 g/m²
ASTM A1046/A1046M-09: ZMM350350 g/m²300 g/m²
AS 1397 extract: ZM275275 g/m²250 g/m²
AS 1397 extract: ZM350350 g/m²315 g/m²

The AS 1397 extract also lists single-spot, single-face minima of 110 and 140 g/m² respectively. The ASTM extract describes at least 40% of the single-spot limit on either face as a normal expectation; it is not worded there as a mandatory single-face minimum. Specify the contractual standard, edition, designation and inspection documents in the order.

350 MPa or 550 MPa for solar racking?

Solaracks’ regular procurement requirement is 350 MPa minimum yield strength. Where the project needs 550 MPa, raise it at enquiry stage because it normally requires special custom production in our supply routes. This is a sourcing observation, not a rule that all 550 MPa steel worldwide is custom-made.

The full grade matters for forming and punching. For example, ArcelorMittal’s table leaves A80 elongation unspecified for standard S550GD+ZM, while S550GD-HyPer®+ZM lists at least 13% for 0.7–5 mm and 14% for 5–6 mm. Those product-specific differences show why “550” alone does not define ductility. A blank table entry does not mean zero elongation. [2]

The designer reviews section strength, stability, deflection and connections; the manufacturer reviews the forming and punching route. Any change of thickness or member spacing needs that design review. The order should state the full steel grade and required mechanical properties, without assuming that a 350 MPa requirement automatically identifies S350GD.

350 MPa and 550 MPa are minimum steel yield-strength requirements, separate from coating mass. Review the section, connections and fabrication route.
Strength selection requires a full grade, section and fabrication review. Solaracks sourcing guidance, October 2026.

Plan stock and custom production as different supply routes

Requested requirementSolaracks procurement experience, October 2026Scheduling implication
275 g/m² coatingMost commonly encountered of these coating optionsMatch it to the approved grade, member dimensions and quantity
310 or 350 g/m² coatingLess commonly stockedRequest a specific stock search; obtain custom-production terms if needed
350 MPa minimum yield strengthRegular strength requirementKeep the complete grade and section requirements in the quotation
550 MPa minimum yield strengthNormally requires special custom productionResolve grade, processing, quantity and delivery early

Stock must match the complete combination. A supplier having 350 g/m² material does not establish availability in the required strength and dimensions. Custom production may mean a larger minimum quantity and longer lead time; the actual quantity and timing are quoted per enquiry.

Procurement flow: submit the complete material specification, check matching stock, then confirm either stock delivery or custom-production minimum order and lead time.
Check the full specification before confirming stock or a custom production route. Solaracks sourcing guidance, October 2026.

What EPC buyers should send in a mounting-system RFQ

Send the site location and exposure information; mounting layout or member drawings; module arrangement and project loads; the consultant’s coating and steel-grade requirements, if already defined; system quantity; and required delivery date. For ground mounting, distinguish above-ground members from foundations or buried parts. The Solaracks RFQ checklists and reference documents help assemble those inputs.

Ask the mounting supplier to return a complete proposed material specification, inspection documents, and separate availability statements for matching stock and custom production. This lets engineering assess the offered system while purchasing compares price and delivery on the same technical basis.

Send your solar mounting RFQ to Solaracks with the site conditions, layout, coating requirement, strength requirement and delivery target. We can then check the actual supply combination before you commit the order.

References and scope

[1] Nippon Steel, ZAM™ catalogue U110en, printed pages 29–32: coating designations, mass acceptance examples and density. Its standard extracts include historical editions; use the applicable contractual edition for an order.

[2] ArcelorMittal, Magnelis® catalogue E35, coating weight, density and structural-grade mechanical properties, accessed 15 October 2026. These are manufacturer-specific examples.

Supply observations: Solaracks procurement guidance confirmed 15 October 2026. Availability and custom-production terms are enquiry-specific. This guide does not extend a product warranty.

Frequently asked questions

Does 275 g/m² mean 275 on each side?

No. Here it means total metallic alloy coating mass on both faces. The ordered standard and test basis define acceptance; equal distribution is not guaranteed.

How thick is a 275 g/m² coating?

Assuming equal distribution, it calculates to about 22.2–22.9 µm per face using densities of 6.2–6.0 g/cm³. This is an illustration, not a guaranteed minimum thickness.

Should every coastal project use 350 g/m²?

No single coating mass qualifies all coastal sites. Use the assessed exposure and approved protection system, including joints, cut edges and any buried parts, to evaluate the proposed material.

Are 310 and 350 g/m² always available from stock?

No. They are less common in Solaracks’ current sourcing experience. A specific stock check is needed; custom production may require a larger order and longer lead time.

Does 550 MPa mean a more corrosion-resistant coating?

No. It describes minimum steel yield strength, not coating mass. The full grade, mechanical properties and fabrication route still need to be specified.

Can a thinner 550 MPa section replace a 350 MPa section?

Only after the project designer reviews the section, stability, deflection, connections and applicable requirements, and the manufacturer reviews fabrication.

Get an engineered mounting quote for your project.

Share drawings, module layout, site location, wind load, snow load and corrosion environment. Solaracks will recommend the system, material, layout and packing approach.

Request a quote