Orientation, wind demand and foundations; conceptual engineering rendering.

Vertical bifacial solar mounting can preserve access between rows and shift generation towards the morning and afternoon. It also changes the structural problem: wind acting normal to a vertical module face produces horizontal force, and raising that face increases the moment transferred to the ground. A useful comparison therefore considers energy, land use, cleaning, wind actions and foundations together.

Concept illustration of vertical bifacial solar fence mounting in an agricultural landscape.

Concept illustration, not a photograph of a completed Solaracks project. Layout and clearances are illustrative.

East-west faces mean a north-south fence line

In the layout discussed here, the fence runs north-south. One module surface faces east and the other west. Direct sunlight reaches the east-facing surface in the morning and the west-facing surface in the afternoon. Near solar noon, direct sunlight is nearly parallel to the module plane, so diffuse sky light and ground-reflected light become particularly important.

The resulting generation profile can have morning and afternoon peaks. Actual timing and peak size depend on weather, shading, module bifaciality and electrical losses. A useful profile for one tariff or load does not automatically have the same value elsewhere. [1][2]

Plan-view diagram distinguishing a north-south fence line from its east-facing morning surface and west-facing afternoon surface.

Name the direction of the fence and the orientation of its faces separately.

What the research tells us

Published comparisons support evaluating vertical bifacial mounting, but they do not provide a universal yield advantage.

EvidenceReported findingBoundary for project decisions
Doha module-level experiment, Kivambe et al. [1]An average energy-yield difference of about 4% favoured clean 22° tilted bifacial modules over clean vertical modulesHigh-albedo desert site; a module-level comparison, not a full commercial fence array
Amman field comparison, Ayadi et al. [3]Annual specific yields of 1,962 kWh/kWp for an elevated 10° tilted bifacial system and 1,288 kWh/kWp for a vertical systemTwo 11.1 kWp systems; crop-free first-year baseline; configuration and site specific
Global model, Khan et al. [2]At 2 m row spacing and 1.2 m panel height, modelled annual energy per land area was typically 10 to 20% higher than the tilt-optimized monofacial comparator across most evaluated regionsAlbedo was 0.5; some locations showed lower vertical output. This land-area comparison is distinct from the kWh/kWp field results above, and the comparator was monofacial, not tilted bifacial

The Doha paper defines an energy-yield difference using the tilted configuration as its reference. Its approximate reported difference should not be converted into a precise cumulative yield ratio from the abstract alone. The Amman annual values give a vertical-to-tilted ratio of 65.6%; that ratio belongs to the tested configurations. [1][3]

Albedo is an input, not a pass/fail threshold. Measure it across relevant seasons and planned ground covers, or test a justified range in the yield model. Compare layouts on the same capacity basis, then examine energy per available land area, hourly export value, cleaning costs and access requirements. Do not choose a layout simply because the site resembles a photograph from a published study.

Compare installed cost and levelized cost of electricity using the same financial basis, service life and operating assumptions. Lower mounting costs alone do not establish a lower cost per unit of electricity: the energy yield and other project costs also matter.

Soiling changes the maintenance comparison

The Doha study found that naturally soiled vertical modules had a maximum monthly average soiling energy loss below 1.53% between May and December 2022. That supports investigating vertical mounting where cleaning is costly. It does not establish an annual limit for other deserts or a maintenance-free design. [1]

A vertical face offers less upward-facing area for settling dust, but deposits can still accumulate. Plan inspection access and choose a cleaning method compatible with the module manufacturer's instructions and the fence geometry. Set the cleaning interval using site monitoring. Include access to both faces, lower edges, connections and cable routes in the maintenance plan.

Establish the wind-design method before sizing posts

A 90° fence is outside the fixed-tilt PV procedure

ICC's explanation of ASCE 7-22 §29.4.5 lists an angle range of 0° < ω < 60°, together with limits on chord length, height, row length, spacing and gaps. A vertical fence lies outside that geometric scope. Its wind coefficients cannot simply be extrapolated from the fixed-tilt procedure. [4]

Freestanding wall or sign provisions, such as ASCE 7-22 §29.3 or the relevant provisions of the project-adopted EN 1991-1-4, may be suitable where their assumptions match the structure. The engineer must justify that applicability. If the geometry or response is not covered, a project-specific method, including wind-tunnel testing where required, may be necessary. Confirm the locally adopted code, edition and any national provisions. [4][5][6]

The wind report should explain:

  • How module gaps, openings and ground clearance are represented.
  • How row ends, eccentric loading and different wind directions are checked.
  • Whether adjacent rows affect the loads and whether any shelter reduction is justified.
  • How overall structural actions and local demands on modules, clamps and connections are established.

Treating a porous face as solid is a modelling choice that needs checking for the load effect considered. It is not a universal guarantee of conservatism. A structural analysis program can calculate the response to specified loads; it does not supply missing aerodynamic evidence by itself.

Worked example: more clearance increases ground-line moment

Consider one interior post in a continuous, regularly spaced fence. It receives half a bay from each side. For this example, assume uniform net design pressure over the panel band and equal tributary load sharing.

Assumed inputValue
Panel-band height2.30 m
Tributary width per interior post2.30 m
Bottom-edge clearance0.70 m
Net design pressure, with required wind factors already included1.20 kN/m²

The tributary area is:

A = 2.30 × 2.30 = 5.29 m²

The horizontal force acting normal to the fence is:

F = pA = 1.20 × 5.29 = 6.348 kN ≈ 6.35 kN

Under the assumed uniform pressure, the resultant acts at the centre of the panel band. Its height above the ground line is:

z = 0.70 + 2.30 ÷ 2 = 1.85 m

The ground-line moment is:

M = Fz = 6.348 × 1.85 = 11.74 kN·m ≈ 11.7 kN·m

If bottom clearance increases to 1.20 m while the force stays unchanged, the lever arm becomes 2.35 m and the moment becomes 14.9 kN·m, an increase of approximately 27%.

Comparison of one interior fence post with 0.7 m and 1.2 m bottom clearance, showing equal 6.35 kN horizontal forces and ground-line moments of 11.7 and 14.9 kN·m.

An illustrative load-and-lever-arm calculation for an interior post. Pressure is assumed; the diagram is not a foundation design.

A higher fence can also change the applicable wind pressure or coefficient, which this fixed-force comparison deliberately holds constant. The 1.20 m clearance is an arithmetic example, not a livestock recommendation. These ground-line calculations do not establish the maximum moment in the embedded pile. That requires analysis of the pile and surrounding soil. Use the design basis and load combinations adopted for the actual project.

Detail the entire load path

Modules and clamps. Check that the proposed vertical orientation, support arrangement and clamping zones are permitted by the module manufacturer's installation manual. Match rail and post spacing to the complete support layout. Module dimensions alone do not determine acceptable support spacing.

Rails, posts and connections. Trace loads through clamps, rails, brackets and posts. Check bending, shear, axial force and torsion where the force and restraint geometry produces it. Open thin-walled sections can be sensitive to torsion and connection rotation. Support stiffness, connection slip and member deformation also affect serviceability.

Shading. Both module faces contribute to output. Include posts, rails, brackets and cable routes in the shading assessment. A narrower member may reduce obstruction, but its section still has to satisfy structural and connection checks.

Foundations. Horizontal wind force and overturning moment can be important for vertical fence piles. The governing checks depend on the support system, other actions and load combinations. Obtain shear, moment and axial reactions per support; use site ground data to assess lateral response, deflection and the necessary axial resistance. Where testing is specified to establish or verify lateral performance, ASTM D3966/D3966M provides methods for static lateral load testing of deep foundation elements. [7] A calculation based only on ground-line moment does not establish embedment depth.

Separate atmospheric and soil exposure

ISO 9223 classifies atmospheric corrosivity. It is useful for above-ground exposure, but it does not directly specify protection for buried piles or establish a universal anodising thickness. [8]

Assess the soil-air transition and buried portion separately. Relevant site information includes soil chemistry, moisture, drainage, groundwater and resistivity. Consider coating damage during handling and installation, dissimilar-metal contacts, detailing that traps moisture, and the required service life. Specify the coating system, fastener compatibility, any corrosion allowance and the inspection plan for each exposure condition.

A fence post divided into above-ground, soil-air interface and below-ground exposure zones, with separate corrosion assessment factors for each.

One post can cross several exposure conditions. An atmospheric category does not replace assessment of buried steel.

Keep agricultural access in the design brief

Open strips between fence rows can support mowing, cropping or grazing, depending on row spacing, machinery, crop needs and management. Agree those activities before fixing the layout.

The NSW Agrivoltaics Handbook advises keeping electrical equipment out of sheep's reach or protecting it where necessary. [9] Cattle introduce a different contact and impact problem. Assess access, rubbing and accidental impact with the farm operator and engineer. Where animals could reach the array, use appropriate barriers or protective elements and keep them away from exposed electrical equipment and module edges.

Do not treat load-bearing rails or posts as sacrificial components. Determine clearances for the actual livestock and equipment, then include the resulting height and exposure in the structural analysis.

What to include in a tender brief

TopicInformation to request
Energy comparisonCommon capacity basis; weather data; albedo assumptions; row pitch; bifaciality; shading and loss models
Wind basisAdopted code and edition; applicability of the selected method; treatment of openings, row interaction, eccentric loads and components
StructureModule support requirements; member and connection checks; serviceability criteria
FoundationsGround investigation; reactions per support; lateral and axial checks; testing requirements
DurabilitySeparate atmospheric and soil exposure assessments; coating and fastener specifications; inspection access
Agricultural useLivestock, equipment envelopes, crop requirements, barriers and cable protection
Commercial comparisonInstalled cost, maintenance, usable land and hourly energy value using common assumptions

For a Solaracks project enquiry, share the site location, module installation manual, proposed layout, wind-design basis, ground information and intended land use. Confirm the engineering scope, materials, coatings, availability and delivery schedule in the project quotation.

Sources

  1. Kivambe, M. et al. (2024). Assessing vertical east-west bifacial photovoltaic systems in desert environments: Energy yield and soiling mitigation. Solar Energy 279, 112835. See experimental details, Eq. (5) and §3.2. Author-uploaded full text.
  2. Khan, M. R., Hanna, A., Sun, X. and Alam, M. A. (2017). Vertical bifacial solar farms: Physics, design, and global optimization. Applied Energy 206, 240 to 248. Author preprint.
  3. Ayadi, O. et al. (2026). Comparative experimental performance assessment of tilted and vertical bifacial photovoltaic configurations for agrivoltaic applications. Sustainability 18(2), 931. See performance comparison and §3.3 economic analysis.
  4. International Code Council. Demystifying Loads: 2024 IBC and ASCE 7-22, Part 2. See ground-mounted fixed-tilt PV applicability and wind-procedure overview.
  5. ASCE/SEI. ASCE 7-22: Minimum Design Loads and Associated Criteria for Buildings and Other Structures. Chapters 29 and 31; apply the project-adopted edition and applicable provisions.
  6. European Commission Joint Research Centre. Eurocode 1: Actions on structures. EN 1991-1-4 covers wind actions; use the applicable edition and national provisions.
  7. ASTM International. ASTM D3966/D3966M-25: Standard Test Methods for Deep Foundation Elements Under Static Lateral Load. Apply the edition specified for the project and the foundation engineer’s test requirements.
  8. ISO. ISO 9223:2012: Corrosion of metals and alloys; Corrosivity of atmospheres; Classification, determination and estimation.
  9. Bomm, A. and Stark, K. (2025). Agrivoltaics Handbook: A guide for solar developers and landholders. NSW Government, EnergyCo, December 2025 edition, p. 23.

Frequently asked questions

Does a vertical bifacial fence produce as much energy as a tilted array?

There is no universal ratio. Site conditions, bifaciality, shading, cleaning and the tilted comparator all matter. Compare both layouts using the same project inputs and evaluate hourly value and land use alongside annual energy.

Does high albedo guarantee that vertical mounting is better?

No. Higher ground reflectance can help bifacial output, but it does not decide the result alone. Use measured or justified albedo values and test sensitivity to seasonal ground cover and row geometry.

Can the fixed-tilt wind coefficients be used for a 90° PV fence?

A 90° fence is outside the geometric scope of ASCE 7-22 §29.4.5. The engineer must justify an applicable alternative. Wall or sign provisions are possible routes where their assumptions fit; they are not an automatic substitute for every fence layout.

How does greater ground clearance affect the foundation demand?

For the same horizontal force, it increases the lever arm and ground-line moment. The worked example rises from 11.7 to 14.9 kN·m. Actual wind actions and soil response must also be checked before sizing the post or foundation.

Can cattle graze between vertical solar rows?

This depends on the livestock and the protective design. Assess contact and impact, protect electrical equipment and module edges, and use appropriate separation where required. A nominal bottom clearance alone does not demonstrate suitability.

Can an ISO 9223 category determine the pile coating?

It describes atmospheric exposure, not the complete buried-pile environment. Assess the soil and transition zone separately and select protection for the required service life and installation conditions.