Dust-aware racking design sets tilt, height, row layout and cleaning access from site soiling evidence. In a Jeddah study, uncleaned modules showed 60.2% power reduction at 25° and 80.4% flat after the same rainless period. A separate Qatar study reported a maximum average monthly soiling energy loss below 1.53% for vertical east-west bifacial modules during May-December 2022. These are study-specific observations, not project yield guarantees. [1][3]

AI product render from a Solaracks assembly reference; not an actual project or foundation design.
Why soiling belongs in the racking specification
IEA-PVPS Task 13 estimates that soiling cost at least 3 to 4% of global PV energy production in 2018, an economic loss of roughly €3 to 5 billion. Its September 2025 fact sheet gives an average global energy loss of 4 to 7%. [6][7] These global estimates provide context; the site needs its own measurements.
Cleaning is the counter-measure, and it sits inside operating cost. The 2022 IEA-PVPS O&M report gives a typical base-scope benchmark, including soiling mitigation, of 6.5 to 16.5 €/kWp per year. [8] This is a historical report benchmark, not a current project quotation. For a 10 MWp plant that is 6.5 × 10,000 = €65,000 to 16.5 × 10,000 = €165,000 per year for the whole base scope, of which cleaning is one part. Racking geometry can affect dust deposition and how easily a robot, vehicle or crew reaches the glass, so tilt, height, row layout and access belong in the same decision as the O&M plan.
What the field and test evidence shows
The three studies below include an 80.4% power reduction on flat uncleaned 10 W modules in Jeddah and a maximum average monthly soiling energy loss below 1.53% for vertical bifacial modules in Doha, and each value holds only for its own metric, period and set-up. [1][2][3]
| Study | Site | Configuration compared | Metric | Value | Scope limit |
|---|---|---|---|---|---|
| Alzahrani et al. 2025 [1] | Jeddah, Saudi Arabia | 0°, 15°, 25°, uncleaned vs cleaned reference | Power reduction at end of the same dry period | 80.4% / 75.6% / 60.2% | 10 W modules; 183 rainless days in the author abstract |
| Alzahrani et al. 2025 [1] | Jeddah | 25° | Reported power reduction over the study year | 20.7% (best tested angle) | Small-module power, not plant energy |
| Alzahrani et al. 2025 [1] | Jeddah | 45° | Reported power reduction in the rainy period | 5.9% (best in that period) | Rainy period only |
| Kivambe et al. 2024 [3] | Doha, Qatar | Clean 22° tilted bifacial vs clean vertical E-W bifacial | Energy over study period | Tilted ≈ 4.0% higher | Oct 2019-Dec 2022; albedo 0.45 ± 0.03 |
| Kivambe et al. 2024 [3] | Doha | Vertical vs tilted, summer months | Energy | Vertical 3.8% higher on average, up to 9.2% | Summer months only |
| Kivambe et al. 2024 [3] | Doha | 22° tilted bifacial vs monofacial | Bifacial gain | 26.5% clean; 36.4% soiled | Tilted configuration only |
| Kivambe et al. 2024 [3] | Doha | Vertical E-W bifacial, naturally soiled | Maximum average monthly soiling energy loss | Below 1.53% | May-Dec 2022; one site |
| Wang et al. 2025 [2] | Wind tunnel | Downstream panels 2 to 4 at 30 to 35° vs 0° tilt | Dust deposition increase | Up to +50% / +200% / +275% | 670 × 350 mm panels at 5 m/s |
Read the table row by row. Each row answers one question under one boundary, which is what makes it useful for shortlisting options before site modelling.
Tilt: compare results from the same observation period
The Jeddah study compared paired polycrystalline modules at several inclinations over 12 months, with a cleaned reference and an uncleaned module. The primary paper’s indexed specification identifies 10 W modules. The author abstract reports 183 rainless days, followed by power reductions of 80.4% at 0°, 75.6% at 15° and 60.2% at 25°. [1]

Jeddah small-module power reductions at 0°, 15° and 25° after the same dry accumulation period [1].
The authors report that 25° performed best among the tested angles over the year, with a 20.7% power reduction, while 45° performed best during the rainy period, at 5.9%. [1] Those period findings must not be combined with the end-of-dry-spell figures as one ranking. The separate Qatar study below supplies the vertical-array comparison.
For a project, treat 25° and the neighbouring angles as candidates and test them in a yield model that carries measured soiling and the planned cleaning regime. State for each figure whether it is instantaneous power, a period statistic or integrated energy.
Height and spacing: measure the site response
Wang and colleagues tested a four-panel array of 670 × 350 mm panels in a 21 m wind tunnel at 5 m/s (18 km/h), varying tilt, mounting height, spacing and flow direction. [2] Deposition on downstream panels peaked at 30 to 35° tilt, up to 50%, 200% and 275% above the zero-tilt case for panels 2, 3 and 4. For a spacing near 1 m, the authors propose that flow interaction may become negligible. Their twice-height comparison uses the upper edge about 0.5 m above ground, not the module chord length. The paper also reports increased deposition beyond 1 m, so the ratio is not a minimum-soiling spacing rule. The authors suggest windbreak walls in front of the array. [2]
The leading panel behaved differently from those behind it and accumulated more dust in the height tests. In the results, deposition on the leading panel rose and then fell as height increased, while deposition on downstream panels declined. [2] Treat the windward edge separately and test whether those patterns apply on site.
To set spacing, combine shading, maintenance access, terrain, drainage, structural constraints and measured soiling. Define whether “spacing” means the clear gap or the row pitch, and state the convention used for any ground coverage ratio. Scaling a tunnel ratio to full size also requires matching particle properties, flow and geometry, so treat the twice-height observation as a hypothesis for field checking.
A practical field check samples exposed and interior rows across the relevant wind directions. The results show whether separate cleaning zones for windward rows pay off. Check any proposed windbreak for its effect on wind pressure, turbulence and sand accumulation before adding it to the layout.
Vertical east-west bifacial: a strong option to model
Kivambe and colleagues compared 22° south-facing tilted bifacial and monofacial modules with vertical east-west bifacial modules in Doha from October 2019 to December 2022, over ground with a daily average albedo of 0.45 ± 0.03. [3] One module of each configuration was cleaned weekly and the other left to soil naturally.
- Clean state: tilted bifacial produced about 4.0% more energy than vertical on average. Expressed with tilted output equal to one, the vertical-to-tilted ratio is 1 / 1.04 = 0.9615 for this study. In summer, vertical produced 3.8% more on average and up to 9.2% more. [3]
- Soiled state: tilted modules lost up to 60% (monofacial). Bifacial gain over monofacial in the tilted set-up rose from 26.5% clean to 36.4% soiled, a 9.9-point increase. [3]
- Vertical soiling: from May to December 2022, the maximum average monthly soiling energy loss of the naturally soiled vertical modules stayed below 1.53%. [3]
A vertical layout changes irradiance on each face, row shading, structural geometry and maintenance method. Model the site’s ground reflectance, seasonal irradiance, rear-side obstructions, soiling and cleaning recovery, then weigh the energy result against foundations, racking, land, cleaning and repair costs. Build cleaning intervals from site measurements for the chosen configuration; the Doha ratio and a soiling rate from another study describe different conditions and do not combine into an interval. A vertical array still needs inspection and a cleaning plan.
Design the structure around the cleaning method
Agree the intended cleaning method before fixing the table layout, because each method creates different access, load and interface requirements. Include the equipment and operating costs in the project-specific O&M budget. [8]
| Cleaning approach | Inputs to settle with the operator or equipment supplier |
|---|---|
| Robotic cleaning | Module-edge alignment, permitted gaps and slopes, operating and parked loads, table transitions, docking and retrieval access |
| Vehicle-assisted cleaning | Access width, turning space, terrain capability, brush reach, drainage and ground-bearing capacity |
| Manual cleaning | Safe reach, work positions, access, fall protection, electrical precautions and approved cleaning methods |
A shading gap and a service aisle are separate requirements; size each for its own purpose. Agree allowable alignment and movement with the cleaning equipment supplier, and coordinate thermal movement details with clamp capacity, bonding and operating tolerances before adding slotted connections or expansion breaks.
Keep structural wind design separate from dust transport
Dust-transport winds explain soiling. Structural design uses the applicable extreme-wind basis, return period, terrain and site factors, so a recorded sandstorm speed informs O&M planning rather than the load case.
ICC training material on ASCE 7-22 describes the fixed-tilt ground-mounted PV procedure (§29.4.5.1) with geometric limits that include 0° < tilt < 60°, plus limits on chord length, height, row spacing and gaps. [4] A 90° vertical fence therefore needs a separate wind method. Check every geometric limit for tilted arrays too.
For vertical or unusual arrays, the designer establishes how gaps, ground clearance, shielding and overall form affect the wind-load approach; a PV fence with open gaps may behave differently from a solid wall. Where Eurocodes or national standards apply, confirm the adopted edition before citing clause numbers.
Base foundation design on the ground investigation and the actual actions, including uplift and lateral response. Include sand movement, erosion and accumulation where site evidence shows them. Foundation cost follows those actions and the soil, so compare options on both.
Treat abrasion and corrosion as different exposures
ISO 9223 classifies atmospheric corrosivity; it is not an abrasion rating. [5] Wind-blown sand causes mechanical wear, while salts and moisture create a separate corrosion exposure, so a site needs both assessed rather than a single “desert” label.
For corrosion, select protection by the ISO 9223 category of the site. Document the project-approved anodising thickness, sealing quality and inspection requirements for the actual component; film thickness alone does not establish C4 or C5 suitability. For steel members, see our analysis of ZAM coating selection by ISO corrosivity category.
For abrasion, inspect the lowest members facing the dust wind, such as post bases and lower rails. Evaluate sleeves, shields or coating upgrades for trapped moisture, drainage and their structural interfaces, and base service-life expectations on exposure and performance evidence for the chosen system. Our guide to corrosion in solar mounting systems covers inspection points for connections, cut edges and ground contact.
Use rain observations to improve the operating model
Rainfall does not provide a universal cleaning credit. The IEA-PVPS fact sheet stresses site-specific measurement and mitigation. [7] In the Qatar field study, a July 2022 rain event restored soiled-module yield to clean-reference levels, but the authors explicitly caution that rain recovery depends on the site and the material deposited. [3]
Record soiling before and after rain alongside routine measurements. Compare each cleaning intervention’s expected energy recovery with its cost, equipment constraints and the remaining dry-period exposure, and update the cleaning plan when operating evidence differs from the design assumptions.
A practical concept-stage workflow
- Establish the baseline. Record irradiance, seasonal dust and rain, ground reflectance where relevant, access and available cleaning methods.
- Define comparable options. Use the same capacity and economic boundary for the selected tilted and, where appropriate, vertical layouts.
- Model energy and operations together. Include measured or explicitly assumed soiling, cleaning recovery, downtime and operating costs.
- Check the structure and site fit. Verify the wind method, foundations, drainage, access and equipment compatibility for each option.
- Test the assumptions. Use a representative monitoring or pilot arrangement where the uncertainty materially affects the choice.
- Specify what to monitor. Include row-position effects, cleaning outcomes and exposure-related wear in the operating plan.
The output is a site-specific configuration and maintenance plan with traceable assumptions. Published angles, height trends and spacing ratios are where the evaluation starts.
How Solaracks supports desert projects
Solaracks can support project-specified structural calculations using static analysis and SAP2000 where required. Confirm the applicable standard, calculation scope and deliverables for the actual configuration with the project team. Share the site’s wind basis, ground investigation, corrosivity category and cleaning method, and we will match the racking and coating specification to them. More engineering notes are collected in our technical articles.
Related guides
- Hybrid ballast-anchor solar racking for Philippine typhoon roofs: from NSCP Zone 1 to NSCP 2015
- Anti-theft solar mounting for Africa: keep clamp capacity while delaying removal
- Solar racking landed cost and import duty to Africa: Nigeria, Kenya and Ghana
Sources
- Alzahrani, M., Rahman, T., Rawa, M., Weddell, A. (2025). Impact of dust and tilt angle on the photovoltaic performance in a desert environment. Solar Energy 288. University of Southampton author repository abstract and indexed paper specification; DOI 10.1016/j.solener.2025.113239.
- Wang, J., Hu, W., Wen, Y., Zhang, F., Li, X. (2025). Dust deposition characteristics on photovoltaic arrays investigated through wind tunnel experiments. Scientific Reports 15, 1582.
- Kivambe, M., Abdallah, A., Figgis, B., Scabbia, G., Abdelrahim, M., Lopez-Garcia, J. (2024). Assessing vertical east-west bifacial photovoltaic systems in desert environments: Energy yield and soiling mitigation. Solar Energy 279.
- ICC. Demystifying Loads: 2024 IBC and ASCE 7-22, Part 2, ground-mounted fixed-tilt PV scope.
- ISO. ISO 9223:2012, Corrosion of metals and alloys; Corrosivity of atmospheres; Classification, determination and estimation.
- IEA-PVPS Task 13. Soiling Losses: Impact on the Performance of Photovoltaic Power Plants, Executive Summary, T13-21:2022.
- IEA-PVPS Tasks 13/16. Fact Sheet: Soiling, 2025.
- IEA-PVPS Task 13. Guidelines for Operation and Maintenance of Photovoltaic Power Plants in Different Climates, T13-25:2022.