Solaracks cable trays and trunking carry and protect power and communication cables in power plants (solar plants included), substations, industrial sites, buildings, tunnels and data centres. There are four tray styles: trough, ladder, trunking and wire mesh. Choose the style for the cable load and access, then the finish for the environment: hot-dip galvanized (HDG) steel for outdoor and heavy-corrosion sites, ZAM (zinc, aluminium, magnesium) coated steel for coastal and chemical sites, anodized aluminium where weight or magnetism matters, and electro-galvanized wire mesh for dry indoor runs. Width, height, length, perforation pattern and wire gauge are made to order for each run.

FitsCable runs in power plants and substations, industrial workshops and warehouses, buildings, tunnels and data centres
Fixes intoSupports and fixings along the run, set for each project
LimitsWire mesh is for indoor, dry or lightly corrosive, light-duty runs; HDG is not for strong-acid or strong-alkali environments; aluminium trays have a lower load capacity and can corrode where they touch other metals
MaterialHDG or ZAM-coated steel, anodized aluminium alloy, or electro-galvanized steel wire
Perforated steel trough cable trays, stacked
Perforated trough trays: width, height, length and perforation pattern are made to order.
Hot-dip galvanized perforated cable traysZAM (zinc, aluminium, magnesium) coated steel cable trays, stackedAluminium cable trunking in three sizesElectro-galvanized wire mesh cable trays

Benefits

  1. Four styles, trough, ladder, trunking and wire mesh, chosen for the cable load and access.
  2. Four finishes for the site: HDG for outdoor and heavy corrosion, ZAM for coastal and chemical sites, anodized aluminium where weight matters, wire mesh for dry indoor runs.
  3. Width, height, length, perforation pattern and wire gauge are made to order for each run.

Compatible roof and site types

  • Power plants, substations and transmission
  • Industrial workshops, warehouses and chemical plants
  • Tunnels, bridges, ports and other outdoor runs
  • Buildings, car parks and data centres

Components

  • Perforated trough cable trayTrough trayOpen channel with a perforated base and sides
  • Ladder cable tray with side rails and rungsLadder trayTwo side rails joined by rungs, open between them
  • Cable trunking with coversTrunkingClosed channel with a cover
  • Wire mesh cable trayWire mesh trayOpen steel wire mesh basket, wire 3.5 to 6.0 mm in diameter, commonly 5.0 mm

Technical parameters

Cable Tray and Trunking Systems: indicative parameters. Final values follow project engineering.
ParameterValueBasis
Tray stylesTrough, ladder, trunking and wire meshSolaracks spec
FinishesHot-dip galvanized (HDG), ZAM (Zn-Al-Mg) coated, anodized aluminium alloy (AL), electro-galvanized wire mesh (WM)Solaracks spec
HDG processDerusted steel immersed in molten zinc at about 500 °C, forming a zinc-iron alloy layerSolaracks spec
HDG zinc coat45 to 200 µmSolaracks spec
HDG useOutdoor and heavy-corrosion sites; heavier, so it needs more support points; not for strong-acid or strong-alkali environmentsSolaracks spec
ZAM coatingZn-Al-Mg alloy coated steel: zinc protects sacrificially, aluminium passivates and magnesium slows coating consumptionSolaracks spec
ZAM useCoastal areas, chemical plants and power plants; industrial workshops and large warehouses; bridges, tunnels and exposed cable runsSolaracks spec
AluminiumAluminium alloy, anodized; light and non-magneticSolaracks spec
Aluminium limitsLower strength and load capacity than steel trays; harder to weld; can corrode where it touches other metalsSolaracks spec
Wire meshElectro-galvanized steel wire, 3.5 to 6.0 mm diameter, commonly 5.0 mm; open mesh for good heat dissipation and easy accessSolaracks spec
Wire mesh useIndoor and lightly corrosive, dry, light-duty runs onlySolaracks spec
Size codeType, then internal height × internal width in mm: WM 50 × 100 is a wire mesh tray 50 mm high and 100 mm wide insideSolaracks spec
Made to orderWidth, height, length, perforation pattern and wire gaugeProject-specific
Supports and fixingsSet for each runProject-specific
WarrantyHDG and ZAM trays: 12 years on the structure, with the hot-dip galvanized coating 5 years or the ZAM coating 10 years; aluminium trays: 12 years, anodized appearance 5 years (Solaracks Limited Warranty SR-WT-001)Solaracks spec

Material and coating options

ParameterValue
MaterialSteel trays, hot-dip galvanized or ZAM (Zn-Al-Mg) coated; aluminium alloy trays, anodized; steel wire mesh trays, electro-galvanized
Finish / coatingHDG: zinc-iron alloy layer, zinc coat 45 to 200 µm. ZAM: Zn-Al-Mg alloy coating. Aluminium: anodized oxide film. Wire mesh: electro-galvanized zinc film

Engineering basis

Solaracks, a solar mounting manufacturer in Xiamen, China, since 2012, makes cable trays and trunking to order for each run. The tray style follows the cable load and how the cables are reached; the finish follows the environment the run passes through. ISO 9223 classifies the site, not the product, and the finish is chosen for that site: HDG for outdoor and heavy-corrosion sites, but not for strong-acid or strong-alkali environments; ZAM for coastal and chemical sites; anodized aluminium where low weight or a non-magnetic tray matters; electro-galvanized wire mesh only indoors or in dry, light-duty runs. HDG trays are heavier and need more support points. Aluminium trays have a lower load capacity, are harder to weld and can corrode where they touch other metals. Send the run, the sizes and the site environment for a tray schedule and quote.

How Solaracks runs wind load calculations →

Installation and packing notes

The tray layout, supports and fixings follow the project drawing for each run. HDG trays are heavier and need more support points. Keep aluminium trays out of direct contact with other metals, and keep wire mesh trays indoors or in dry, light-duty runs.

Check the runs once a year: re-tighten loose fixings, and touch up scratched zinc on HDG or ZAM trays with zinc-rich paint of 70% zinc or more.

Trays are made to order and ship stacked; each quote confirms the sizes, quantities and lead time.

Packing and installation control →

Downloads

Related systems and guides

Structural design & quote: 24 h

Frequently asked questions

Which tray style should I choose?

Choose the style for the cable load and access first: trough, ladder, trunking or wire mesh. Then choose the finish for the environment the run passes through.

Which finish suits my site?

HDG for outdoor and heavy-corrosion sites such as power plants, ports and docks, but not for strong-acid or strong-alkali environments. ZAM for coastal and chemical sites, power plants and data centres. Anodized aluminium where low weight or a non-magnetic tray is wanted. Electro-galvanized wire mesh only indoors, or in dry, lightly corrosive, light-duty runs.

How is a tray size written?

As the type, then the internal height and internal width in mm. WM 50 × 100 is a wire mesh tray 50 mm high and 100 mm wide inside; the length is made to order.

What can be made to order?

Width, height, length, perforation pattern and wire gauge. Mesh trays use wire of 3.5 to 6.0 mm diameter, most often 5.0 mm.

How thick is the zinc on HDG trays?

Derusted steel is immersed in molten zinc at about 500 °C to form a zinc-iron alloy layer, with a zinc coat of 45 to 200 µm.

When are aluminium trays the right choice?

Where low weight or a non-magnetic tray matters. They are anodized. They have a lower load capacity than steel trays, are harder to weld and can corrode where they touch other metals, so avoid direct contact with other metals.

What warranty comes with the trays?

Under Solaracks Limited Warranty SR-WT-001: HDG and ZAM trays 12 years on the structure, with 5 years on the hot-dip galvanized coating or 10 years on the ZAM coating; aluminium trays 12 years, with 5 years on the anodized appearance.

What should I send for a quote?

The tray style and finish, the internal height and width of each size, the run lengths or a route drawing, the perforation pattern or wire diameter, the quantities, and whether the run is indoors or outdoors, with the distance to the sea or the ISO 9223 class.

Get an engineered mounting quote for your project.

Share drawings, module layout, site location, wind load, snow load and corrosion environment. Solaracks will recommend the system, material, layout and packing approach.

Request a quote
×

Request this document

Enter your company and contact details. We review each request and email you a download link once it is approved.

Requested document Requested document

Close