SR-F10 mounts solar on TPO and PVC single-ply membrane roofs while the membrane stays watertight. Three mounts cover the deck and insulation: a heavy-duty penetrating mount for rockwool below 180 kg/m³, a mini penetrating mount for firmer insulation, and a clamp type that hot-melt welds to the membrane and never pierces it. Penetrating mounts fix to the deck with expansion bolts or rivet nuts, and their skirts are hot-air welded to the membrane and vacuum-tested. A C rail on the mounts carries SR-R83P rails and the module clamps.

FitsTPO and PVC single-ply membrane roofs over concrete or metal decks
Fixes intoPenetrating mounts: the deck, with expansion bolts (concrete) or rivet nuts or self-tapping screws (metal). Clamp type: welded to the membrane only
LimitsMount choice follows the insulation: heavy-duty below 180 kg/m³ rockwool density, mini and clamp type above. Membrane welding by a trained roofer
SR-F10 modules on SR-R83P rails over C rails on membrane roof mounts
Mounts welded into the membrane carry a C rail, the SR-R83P rails and the modules.
SR-F10 rails on membrane roof mounts on a commercial roofSR-F10 penetrating mount section: welded cylinder, support discs, thermal-break screw and rivet nutSR-F10 section: mount 55 mm, C rail 60 mm, SR-R83P 83 mm, module 30 mm, 228 mm in totalSR-F10 modules installed on a membrane roof

Benefits

  1. The roof stays sealed: skirts are welded into the membrane, with a self-healing film and a thermal-break screw under each penetrating mount.
  2. Three mounts for every deck and insulation, including a clamp type that never pierces the membrane.
  3. One supplier for mounts, C rail, SR-R83P rails and clamps, with 12 years under SR-WT-001.

Compatible roof and site types

  • TPO membrane roofs
  • PVC membrane roofs
  • Concrete decks (expansion bolts)
  • Metal decks (rivet nuts or self-tapping screws)
  • Framed modules

Components

  • Heavy-duty mountPenetrating: SS304 cylinder φ28 × 50 mm laser-welded to a φ240 mm TPO or PVC skirt, φ140 mm supporting base, 0.55 kg; design load 2750 N; for rockwool below 180 kg/m³
  • Mini mountPenetrating: the same SS304 cylinder on a φ120 mm skirt, φ50 mm supporting base, 0.33 kg; design load 2750 N; for rockwool above 180 kg/m³
  • Clamp-type mountNon-penetrating: TPO or PVC base hot-melt welded to the membrane with an aluminium clamp, 180 × 165 × 70 mm, 0.28 kg; design load 1500 N; also for cable trays, inverters, walkways and A/C units
  • C railAluminium C rail bolted to the tops of the mounts through its bottom holes; carries the module rails
  • Rail SR-R83P83 mm anodized 6005-T5 aluminium rail; fixed to the C rail with one rail clamp on each side
  • Inter clampSlides into the SR-R83P channel and holds two module frames
  • End clampHolds the last module in each row; Allen bolt to 15 to 17 N·m
  • SR-EW1 earthing clip that bites through the anodizing of both module framesEarthing clip SR-EW1Stainless steel 304 clip under each inter clamp; its teeth bite through the anodizing of both frames and bond them to the rail
  • SR-GL1 grounding lug that lands the earth conductor on the railGrounding lug SR-GL1Un-anodized aluminium body with a toothed SS304 clip; one per continuous rail run lands the earth conductor

Technical parameters

Membrane-Roof Mount SR-F10: indicative parameters. Final values follow project engineering.
ParameterValueBasis
Roof typesTPO and PVC single-ply membrane roofs over concrete or metal decksSolaracks spec
Heavy-duty mountPenetrating; SS304 cylinder φ28 × 50 mm, φ240 mm membrane skirt, φ140 mm supporting base, 0.55 kg; for rockwool below 180 kg/m³Solaracks spec
Mini mountPenetrating; SS304 cylinder φ28 × 50 mm, φ120 mm membrane skirt, φ50 mm supporting base, 0.33 kg; for rockwool above 180 kg/m³Solaracks spec
Clamp-type mountNon-penetrating; TPO or PVC base with aluminium clamp, 180 × 165 × 70 mm, 0.28 kg; UV resistance ≥ 5000 h; for rockwool above 180 kg/m³Solaracks spec
Design load per mountHeavy-duty and mini 2750 N; clamp type 1500 N, tensile ≥ 3000 N, compressive ≥ 300 kgSolaracks spec
Waterproofing (penetrating mounts)Laser seamless weld of skirt and cylinder; φ50 water-melting self-healing film; thermal-break screwSolaracks spec
Deck fixing (penetrating mounts)Expansion bolts into a concrete deck; rivet nuts, or self-tapping screws as an option, into a metal deckSolaracks spec
Membrane jointSkirt hot-air welded to the roof membrane and checked with a vacuum leak detectorSolaracks spec
Rail buildC rail bolted to the mounts; SR-R83P rails on the C rail with one rail clamp on each sideSolaracks spec
Build heightAbout 228 mm from membrane to module top: mount 55 mm, C rail 60 mm, SR-R83P 83 mm, module 30 mmSolaracks spec
Mount spacingSet from the mount design load, the roof zone and the site wind and snow loadsProject-specific
Roof zonesEdge and corner zones take more ballast or anchorage than the middle of the roof; the calculation sets each zoneProject-specific
Clamping zoneWithin L/4 of each frame end, never on the glass; check the module maker's manualSolaracks spec
Snow loadPer siteProject-specific
Material6005-T5 aluminium, anodized; tensile strength 260 MPa, yield 240 MPaSolaracks spec
BoltsA2-70 (304) below C4; A4 (316) at C4 and aboveSolaracks spec
TorqueModule clamps 15 to 17 N·m with a torque wrenchSolaracks spec
GroundingSR-EW1 clips pressed into the rail channel under the inter clamps and SR-GL1 lugs on the rails; continuity checked before the array is energisedSolaracks spec
Warranty12 years on mounts, rails, clamps and stainless parts (SR-WT-001)Solaracks spec

Material and coating options

ParameterValue
MaterialSS304 cylinders with TPO or PVC skirts (penetrating mounts); TPO or PVC base with aluminium clamp (clamp type); 6005-T5 aluminium C rail and SR-R83P rails; stainless steel bolts
Finish / coatingAnodized: 12 µm standard; 15 µm for C4 and 20 µm for C5 sites

Engineering basis

Solaracks, a solar mounting manufacturer in Xiamen, China, since 2012, calculates every SR-F10 array for its site. Wind and snow loads come from the project's code, such as ASCE 7-22, JIS C 8955, or the AS/NZS 1170 and EN 1991-1 series. Static checks follow that code, and the frame is modelled in SAP2000 where the layout needs it. On a flat roof the edge and corner zones see the highest uplift, so ballast and anchorage are set zone by zone. ISO 9223 classifies the site, not the product; the anodizing and bolt grades in the parameter table are the Solaracks specification for each class. Each mount has a design load: 2750 N for the heavy-duty and mini mounts and 1500 N for the clamp type. The calculation sets the mount type and spacing for each roof zone so that no mount exceeds it. Profiles are anodized before they are cut and drilled, so cut ends and bolt holes are bare aluminium. Send complete site data and the structural design and quote come back within 24 hours.

  • ASCE 7-22
  • AS/NZS 1170.2
  • JIS C 8955
  • EN 1991-1-4
  • ISO 9223 (site corrosivity)

How Solaracks runs wind load calculations →

Installation and packing notes

  1. Mark each mount position from the layout drawing and the hole for each mount on the roof.
  2. Concrete deck: drill and set the expansion bolts. Metal deck: set the rivet nuts with a rivet gun, or use self-tapping screws.
  3. Fit each mount and tighten it with a wrench, hot-air weld its skirt to the roof membrane, then check every weld with a vacuum leak detector.
  4. Align the bottom holes of the C rail with the tops of the mounts and bolt them together; join C rails with the rail joiner.
  5. Fix the SR-R83P rails on the C rails with one rail clamp on each side of the rail, tightened into the C rail slot.
  6. Place the modules: tighten the end clamps to 15 to 17 N·m; press an SR-EW1 clip into the rail channel, slide the inter clamp onto it, set it loosely, slide the next module against it and tighten to 15 to 17 N·m.
  7. Earth the array: fit one SR-GL1 lug per continuous rail run, land the earth conductor and check continuity before the array is energised. Electrical work by a qualified electrician, to local code.

Inspect the membrane welds around every mount once a year and after a severe storm, re-check the torque of every bolt and make sure no clamp has lifted from its module.

Frames, rails, clamps and fasteners ship on pallets and in boxes by type, each with a packing list and part labels. Standard items usually ship in 15 to 20 days; each quote confirms the date.

Packing and installation control →

Downloads

Related systems and guides

Calculation basis: AS/NZS 1170.2 / ASCE 7-22Structural design & quote: 24 hWarranty: 12 years

Frequently asked questions

Which SR-F10 mount do I need?

It follows the insulation and whether the membrane may be pierced. Heavy-duty for rockwool below 180 kg/m³; mini for rockwool above 180 kg/m³; clamp type, above 180 kg/m³, where the membrane must not be penetrated.

How does a penetrating mount keep the roof watertight?

Its skirt is hot-air welded to the membrane and vacuum-tested. Under it, the skirt is laser-welded to the cylinder in one seamless joint, a φ50 water-melting film reseals the contact point if water ever gets in, and a thermal-break screw stops the cold bridge through the deck.

What can the clamp-type mount carry?

1500 N design load, with tensile strength of at least 3000 N and compressive strength of at least 300 kg. Besides PV, it suits cable trays, inverters, walkways and A/C units.

Which roof decks does SR-F10 fix to?

Concrete decks with expansion bolts, and metal decks with rivet nuts or self-tapping screws. The clamp type is welded to the membrane and does not fix to the deck.

How high does an SR-F10 array stand?

About 228 mm from the membrane to the top of the module: mount 55 mm, C rail 60 mm, SR-R83P rail 83 mm and module 30 mm.

What warranty comes with SR-F10?

12 years on the mounts, rails, clamps and stainless parts under Solaracks Limited Warranty SR-WT-001.

How fast can I get an SR-F10 design and quote?

Within 24 hours of receiving complete site data: the roof type and a layout, the location or design wind speed and snow load, and the module model. Standard items usually ship in 15 to 20 days; each quote confirms the date.

What should I send for an SR-F10 quote?

The membrane type and thickness, the deck type, the insulation type and density, whether the membrane may be penetrated, the building height, the module model and layout, and the site location or design wind and snow loads.

Get an engineered mounting quote for your project.

Share drawings, module layout, site location, wind load, snow load and corrosion environment. Solaracks will recommend the system, material, layout and packing approach.